allways disable the Trace on SEPM

$
0
0

HI All

Good Day ..

Must Disable the Tace on SEPM because it is a known problem with SEP. usually auditing people will find the following on environment.

Error

Error:"Trace method must be disabled, port 8014"

Environment

SEP Version: SEP 12.1
Server Operating System: Windows Server 2008 R2- Standard Edition
 

Cause

- How to disable the Trace?

Solution

- Go to C:\Program Files\Symantec\Symantec Endpoint Protection Manager\apache\conf folder

- Open httpd.conf in notepad and add "TraceEnable off" in the file and save the file.

- It will turn off the Trace.

- Restart the Apache web server and SEPM services from services.msc

As per tech Article TECH173154

 

Regards